RunModerate evidenceTraining Data & Wearables

Watch VO2max estimates are close to lab values on average but can be roughly 10 ml/kg/min out for an individual, and watch-style race predictions tend to be optimistic

Interpretation

A meta-analysis of 14 validation studies (Molina-Garcia 2022) found near-zero average bias for exercise-based estimates (-0.09 ml/kg/min) but limits of agreement of about ±10, and overestimation by resting-based devices (2.17; limits -13.07 to 17.41). Later single-device studies agree on individual error: MAPE 7.05% in 19 adults (Carrier 2025), 13.31% with 6.07 underestimation in 30 adults (Lambe 2025), 7.2-7.9% in 35 athletes with larger underestimation (6.3) in the highly trained (Engel 2026), and overestimation of 2.6-2.9 units in 20 runners (Howard 2026). Race predictions: half-marathon predicted 129.97 vs actual 137.55 min (Howard 2026); the Riegel formula was at least 10 min too fast for the marathon for half of 2,303 runners (Vickers 2016). Graded moderate: consistent direction, but small samples, few women reported, no triathletes, and device software changes quickly.

Practical implication

Read watch VO2max as a trend over weeks, check it against field tests and race results, and don't set race pace from watch predictions, which assume a standalone run on fresh legs. Triathlon runs come after a swim and bike, so predictions are an upper limit at best; this transfer is inference, as no study has tested watch predictions for triathlon.

Sources

6 sources, independently verified.

Meta-analysisIndependently verified
Validity of estimating the maximal oxygen consumption by consumer wearables: a systematic review with meta-analysis and expert statement of the INTERLIVE Network ↗
Molina-Garcia P, Notbohm HL, Schumann M, Argent R, Hetherington-Rauth M, Stang J, Bloch W, Cheng S, Ekelund U, Sardinha LB, Caulfield B, Brønd JC, Grøntved A, Ortega FB · 2022 · Sports Medicine
14 validation studies of wearable VO2max estimates against laboratory tests

Wearables using resting information overestimated VO2max (bias 2.17 ml/kg/min; limits of agreement -13.07 to 17.41); exercise-based algorithms showed lower error (bias -0.09; limits -9.92 to 9.74). Exercise-based estimates may suit population-level use, but individual error is large. Proposes six-domain validation standards.

Peer-reviewed studyCross-sectionalIndependently verified
Validation of aerobic capacity (VO2max) and pulse oximetry in wearable technology ↗
Carrier B, Marten Chaves S, Navalta JW · 2025 · Sensors
19 apparently healthy adults, active and sedentary (sex split not given in abstract)

A multisport watch (2019 model) estimated VO2max with MAPE 7.05% and Lin's concordance 0.73 against 30-s averaged laboratory data, meeting the authors' criteria (MAPE < 10%, CCC > 0.7); its pulse-oximetry readings failed validation.

Peer-reviewed studyCross-sectionalIndependently verified
Investigating the accuracy of Apple Watch VO2 max measurements: a validation study ↗
Lambe R, O'Grady B, Baldwin M, Doherty C · 2025 · PLOS One
30 healthy adults, described by the authors as a sex-balanced cohort

After 5-10 days of wear, a general-purpose smartwatch (2023 models) underestimated treadmill-measured VO2max by 6.07 ml/kg/min (95% CI 3.77-8.38), limits of agreement -6.11 to 18.26, MAPE 13.31%, mean absolute error 6.92 ml/kg/min.

Peer-reviewed studyCross-sectionalIndependently verified
Validity of VO2max estimates from the Forerunner 245 smartwatch in highly vs. moderately trained endurance athletes ↗
Engel FA, Masur L, Sperlich B, Düking P · 2026 · European Journal of Applied Physiology
35 endurance athletes (24 M, 11 F), 25.1 ± 3.5 y, lab VO2max 60.1 ± 8.2 ml/kg/min

A running watch (2019 model) underestimated VO2max after two 15-min outdoor runs by 4.73 and 4.05 ml/kg/min (MAPE 7.9% and 7.2%; ICC 0.71 and 0.75). Moderately trained athletes: MAPE 2.8-4.1%; highly trained (lab VO2max > 59.8): underestimated by 6.3 ml/kg/min, MAPE 9.4-10.4%. Published online 2025.

Peer-reviewed studyObservationalIndependently verified
Validity of the Garmin Forerunner 265 to predict VO2max and race performance times ↗
Howard J, Ellis R, Fortner CK, Doyle JA, Otis J · 2026 · Journal of Medical Engineering & Technology
20 runners through 12 weeks of half-marathon training (sex split not given in abstract)

A running watch (2023 model) overestimated VO2max at baseline (43.95 vs 41.10 ml/kg/min) and after 12 weeks (45.00 vs 42.43); its half-marathon predictions (129.97 min) were significantly faster than actual race times (137.55 min). MAPE for VO2max and prediction was under 10%. Online ahead of print; no volume or issue yet.

Peer-reviewed studyCross-sectionalIndependently verified
An empirical study of race times in recreational endurance runners ↗
Vickers AJ, Vertosick EA · 2016 · BMC Sports Science, Medicine and Rehabilitation
2,303 recreational endurance runners (internet survey)

The Riegel race-time formula was well calibrated for races up to the half-marathon but dramatically underestimated marathon time, giving times at least 10 min too fast for half of runners; models including training data (e.g. weekly mileage) predicted marathon time better (mean squared error 381 for Riegel vs 228 and 208). Self-reported survey data.