RunModerate evidenceTraining Data & Wearables

Wrist optical heart rate is close to a chest strap during steady running but less reliable while cycling and in sprints and short efforts, where an electrode strap remains the better reference

Interpretation

Consistent direction across a meta-analysis and several validation studies. Zhang 2020 (44 studies, 15 brands): mean wrist error -0.51 bpm on the treadmill but -4.55 bpm cycling and -7.26 bpm in resistance training. Gillinov 2017 (50 adults, 54% women): chest strap rc = 0.996 vs ECG; wrist devices 0.67-0.92; only three of five optical devices acceptable cycling. Pasadyn 2019 (50 athletic adults, 68% men): strap rc = 0.98, wrist 0.89-0.96 running. Muggeridge 2021 (20 adults, 9 women): optical sensors less valid in sprints; wrist band limits of agreement -46 to 33 bpm. Gilgen-Ammann 2019 (10 adults): strap detected 99.6% of beats. Graded moderate, not strong: samples are mostly healthy non-athletes, stages were short, and every device tested (2015-2019) has since been replaced, so current-model accuracy is unknown.

Practical implication

Use wrist heart rate for steady, easy running; use an electrode chest strap for cycling, intervals, zone tests and beat-to-beat data, or check your own watch against a strap on typical sessions. Device studies date quickly, and no study tested trained triathletes over long sessions. A wearable is not a medical device: wrist sensors underestimated heart rate in atrial fibrillation (Al-Kaisey 2020, 32 patients), so symptoms or rhythm alerts need a doctor.

Sources

8 sources, independently verified.

Peer-reviewed studyCross-sectionalIndependently verified
Variable accuracy of wearable heart rate monitors during aerobic exercise ↗
Gillinov S, Etiwy M, Wang R, Blackburn G, Phelan D, Gillinov AM, Houghtaling P, Javadikasgari H, Desai MY · 2017 · Medicine & Science in Sports & Exercise
50 healthy adults (54% female, 38 ± 12 y)

Against ECG across treadmill, bike and elliptical at rest to vigorous intensity: electrode chest strap rc = 0.996; best wrist device rc = 0.92, others 0.83 and 0.81, a forearm optical band 0.75 and one wrist device 0.67. Most devices rc 0.88-0.93 on the treadmill; only three of five optical devices acceptable (rc > 0.80) cycling; none accurate on the elliptical with arm levers. Devices of the time; healthy adults, not athletes; short stages.

Peer-reviewed studyCross-sectionalIndependently verified
Accuracy of commercially available heart rate monitors in athletes: a prospective study ↗
Pasadyn SR, Soudan M, Gillinov M, Houghtaling P, Phelan D, Gillinov N, Bittel B, Desai MY · 2019 · Cardiovascular Diagnosis and Therapy
50 healthy athletic adults (68% male, mean age 29)

Treadmill running at 4-9 mph (2 min per stage) against ECG: chest strap rc = 0.98; best wrist device rc = 0.96; three other wrist devices rc = 0.89. Running only; 2017-2018 devices.

Meta-analysisIndependently verified
Validity of wrist-worn photoplethysmography devices to measure heart rate: a systematic review and meta-analysis ↗
Zhang Y, Weaver RG, Armstrong B, Burkart S, Zhang S, Beets MW · 2020 · Journal of Sports Sciences
44 studies, 738 effect sizes, 15 brands, against ECG or chest strap

Mean difference versus criterion: -0.01 bpm at rest, -0.40 bpm in sleep, -0.51 bpm during treadmill walking and running, -4.55 bpm cycling and -7.26 bpm in resistance training, with error rising about 3 bpm per 10 bpm increase in heart rate during resistance training. Acceptable validity for most common activities; mostly non-athlete samples and older devices.

Peer-reviewed studyCross-sectionalIndependently verified
Measurement of heart rate using the Polar OH1 and Fitbit Charge 3 wearable devices in healthy adults during light, moderate, vigorous, and sprint-based exercise: validation study ↗
Muggeridge DJ, Hickson K, Davies AV, Giggins OM, Megson IL, Gorely T, Crabtree DR · 2021 · JMIR mHealth and uHealth
20 healthy adults (9 F, 11 M, 40 ± 10 y)

Against an electrode chest strap: an upper-arm optical sensor had bias -1 bpm (limits of agreement -20 to 19, r = 0.95); a wrist band underestimated by 7 bpm (limits -46 to 33, r = 0.8). Both were less valid during maximal bike and treadmill sprints than steady exercise; the wrist band was particularly poor cycling. One model of each device type.

Peer-reviewed studyCross-sectionalIndependently verified
Investigating sources of inaccuracy in wearable optical heart rate sensors ↗
Bent B, Goldstein BA, Kibbe WA, Dunn JP · 2020 · npj Digital Medicine
53 adults completing protocol (32 F, 21 M, 18-54 y), evenly spread across Fitzpatrick skin tones

No statistically significant difference in optical heart rate accuracy across skin tones; significant differences between devices and activity types, with absolute error during activity on average about 30% higher than at rest; devices differed in responding to changes in activity. Rest, breathing, walking and typing, not hard exercise.

Peer-reviewed studyCross-sectionalIndependently verified
RR interval signal quality of a heart rate monitor and an ECG Holter at rest and during exercise ↗
Gilgen-Ammann R, Schweizer T, Wyss T · 2019 · European Journal of Applied Physiology
10 healthy individuals (sex split not given in abstract)

Consumer chest strap correctly detected 99.6% of RR intervals overall and 99.4% during high-intensity activities, versus 94.6% and 89.8% for a Holter ECG; correlation r = 0.997. Very small sample.

Peer-reviewed studyObservationalIndependently verified
Accuracy of wrist-worn heart rate monitors for rate control assessment in atrial fibrillation ↗
Al-Kaisey AM, Koshy AN, Ha FJ, Spencer R, Toner L, Sajeev JK, Teh AW, Farouque O, Lim HS · 2020 · International Journal of Cardiology
32 ambulatory patients referred for Holter monitoring (26 persistent atrial fibrillation, 6 sinus rhythm)

Smartwatches agreed with Holter in sinus rhythm (bias < 1 beat) but underestimated heart rate in atrial fibrillation (bias -9 beats overall), worsening at higher rates: -28 at 100-120, -48 at 120-140 and -69 above 140 bpm. Patients, not athletes.

Expert consensusIndependently verified
Recommendations for determining the validity of consumer wearable heart rate devices: expert statement and checklist of the INTERLIVE Network ↗
Mühlen JM, Stang J, Lykke Skovgaard E, Judice PB, Molina-Garcia P, Johnston W, Sardinha LB, Ortega FB, Caulfield B, Bloch W, Cheng S, Ekelund U, Brønd JC, Grøntved A, Schumann M · 2021 · British Journal of Sports Medicine
Expert statement informed by a systematic review of 44 validation studies

Best-practice validation framework for PPG heart rate wearables across six domains (target population, criterion measure, index measure, testing conditions, data processing, statistics), with checklists; calls for testing against a proper criterion across realistic activities and intensities.